Anaeston 3000

Anaeston 3000 anesthesia machine provides an affordable and flexible anesthesia solution for now and the future. Our customers can start with routine application. The anesthesia machine is upgradeable to better meet customers' anesthetic requirements. Modern anesthetic workstation expansion is also feasible to greatly improve the workflow and cut down the operating cost.
povpraševanje 
  • Pregled
  • dokumenti
  • Podobni izdelki

 

  1. Anestetik stroj ponuja funkcijo elektronskega peep.
  2. Ima avtomatsko kompenzacijo plimovanja glasnosti, razen Anaeston 3000C.
  3. To zagotavlja visoko natančnost izhod tako nizko, kot 20 ml.
  4. Anestetik Naprava uporablja avtoklavabilne in lateksa komponent.
  5. To lahko enostavno vzdrževati in čistiti brez posebnih orodij.
  6.  To je potrjeno CE, ki uporabnikom dušni mir. 

aplikacije 

 Anaeston 3000 anestezijski aparati se lahko uporabljajo za inhalacijske dostavo anesteziji in upravljanje za odrasle, pediatrične in neonatalne bolnikov.

Lastnosti Anaeston 3000 Anestezija stroj   

Model

Anaeston 3000P

Anaeston 3000PS

Anaeston 3000C

razsežnost

810x810x1360 mm (ŠxGxV)

810x810x1360 mm (ŠxGxV)

810x634x1360 mm (ŠxGxV)

Utež

96kg

96kg

70kg

uparjalnik

1 (sekundarni ni obvezna)

1 (sekundarni ni obvezna)

1 (sekundarni ni obvezna)

anestetik tip

Halotan, enfluran, Izofluran,
Sevofluran, desfluran

Halotan, enfluran, Izofluran,
Sevofluran, desfluran

Halotan, enfluran, Izofluran,
Sevofluran, desfluran

oskrba s plinom

O 2ali O 2+ N 2O ali O 2+ N 2O + Klimatska

O 2ali O 2+ N 2O

ali O  + N  O

vhodni tlak

280 ~ 650 kPa

280 ~ 650 kPa
(Priporoča 350 ~ 400kpa)

280 ~ 650 kPa
(Priporoča 350 ~ 400kpa)

Standardna vent. način

VCV, PCV, PLV

VCV, PCV, PLV

VCV, PLV

Neobvezno vent. način

PCV, PSV, SIMV + VCV + PS, SIMV + PCV + PS

PCV (za 3000PS)

neobvezno mehanska PEEP

elektronski PEEP

DA

DA / NE

NE

zaslon

Vgrajen 8.4 "barve

Vgrajen 5.7 "črno-bele

Vgrajen 3.0 "LCD / LED

prikazana vrednost (Set in izmerjena)

Dihalna prostornina, min volumen, hitrosti dihanja, I: E razmerje, tlak meja
Airway tlak (ppeak, Pmean, Pmax, Pplateau, PEEP)
Fio 2%, ustreznosti (ml / CMH 2O) raven podpore tlaka, vdihavanja Okno, P- sprožilec, vdihavanja Konec
EtCO 2 in Inco 2 (neobvezno)
CSI, BS%, SQI%, EMG%

Dihalna prostornina, min volumen, hitrosti dihanja, I: E razmerje, tlak meja
Airway tlak (ppeak, Pmean, Pmax, Pplateau, PEEP)
Fio 2%, ustreznosti (ml / CMH 2O)

Dihalna prostornina, min volumen, hitrosti dihanja, I: E razmerje, tlak meja
Airway tlak (ppeak, Pmean, Pmax, Pplateau, PEEP)
Fio 2%

grafični prikaz

PT, FT, VT valovne oblike
PV, PF, FV zank (skladnost, odpornost, uhajanje analiza)
EtCO 2 valovne (kadar ni obvezno EtCO 2 je modul prisoten)
CSI, BS%, SQI, EMG oblike valov (kadar je neobvezno CSM prisoten)

PT

PT

dodatni razširitveni

Anestetik plinov in hlapov sistem
EtCO 2 modula (mainstream / sekundarnim)
sistem za upravljanje Anestezija informacije
za zunanje bolnika spremljati
Ostala oprema

Anestetik plinov in hlapov sistem
sistem za upravljanje Anestezija informacije
za zunanje bolnika spremljati
Ostala oprema

Anestetik plinov in hlapov sistem
sistem za upravljanje Anestezija informacije
za zunanje bolnika spremljati
Ostala oprema

 

Brchure_Anesthesia Machine_Anaeston3000_EN

Copyright © 2017 Heal Force. Vse pravice pridržane.
WhatsApp Online Chat!